Sensor & Wire-saving Link System S-LINK - İstanbul Otomasyon Sistemleri
  • Information
  • Applications
  • Order Guide
  • CAD DATA
  • Video
  • Catalogs
  • Software
  • Manuals

Sensor & Wire-saving Link System S-LINK


S-LINK transmits 128 points on two signal lines, and "T"-branch multi-drop system enabling flexible cable layout

Sensor & Wire-saving Link System S-LINK
CE Marking

CE Approved
CE : EMC Directive(Excluding some models) 

Features

We've realized a wire-saving system that's easy to use

We've realized a wire-saving system that's easy to use

High noise immunity

Large voltage amplitude (24 V) and wide pulse width (35 μs) signal transmissions make for units less prone to impulse noise effects with no code errors. This high level of noise proofing enables them to be used even in worksites with conventional, high-priced optical communication remote I/O units.

Specifies malfunctioning S-LINK I/O devices

In the event that verification cannot be obtained from an S-LINK I/O unit, such as if the main cable is cutoff, the address of the particular unverifiable S-LINK I/O unit is specified and displayed allowing equipment recovery time to be greatly reduced.

Specifies malfunctioning S-LINK I/O devices

Alleviates the burden laid on engineer for designing and wiring

Labor-saving hook-up connectors are used enabling multiple "T"-branch hookups.
It goes without saying that cascade wiring (bus wiring) as well as multiple branch wiring (star wiring) is also possible.

Alleviates the burden laid on engineer for designing and wiring

Simple and reliable connections

We've provided all types of hook-up connectors. Connections from S-LINK I/O devices to the main cable and from sensors and other devices to S-LINK I/O devices are all realized with one-touch hook-up connectors. They can be connected anywhere quickly and maintenance is easy.

Branch cable to main cable connection and S-LINK I/O device to main cable connection

* The values in ( ) represent conductor cross-section areas.

In addition, to enhance the reliability of the crimping, S-LINK exclusive pliers are made available so that anyone can do it with ease.

Connection from various connected units to S-LINK I/O devices

* The values in ( ) represent conductor cross-section areas.

Connected device extensions

* The values in ( ) represent conductor cross-section areas.

Direct main cable connecting of sensors and actuators possible

All types of transmission line direct-connecting type sensors are made available. Even partner makers are putting on the market manifold electromagnetic valves and limit switches that can be directly connected with the S-LINK system making wire-saving and labor-saving a reality.

Direct main cable connecting of sensors and actuators possible

[Item offered by partner makers]

Mid-system main / branch cable installation and removal possible

For conveyors or other large scale equipment, transport can also be done after dividing the whole into units of several meters in length right at the factory. Then, reassembly and wiring can be effectuated onsite afterwards. Because the S-LINK can be easily divided even from mid-system main / branch cables with the help of commercially available connectors and terminals, the segmented equipment can be wired up prior to transport. Once onsite, assembly work is all but complete with just the connecting of the individual units to each other.
In addition, when assembling the equipment, the S-LINK can work even disconnected from the PLC enabling software (PLC programming) and hardware (machine assembly, I/O check) work to be done concurrently, which results in quick delivery time. With the handy monitor, I/O devices can be checked for each piece of equipment separately enabling subcontractors to conduct check work on delivery. This results in a total delivery deadline reduction and clearly defined subcontractor responsibilities. Also, checking can be performed even without programming so you’ll know immediately if malfunctions are coming from the PLC or the S-LINK.

Mid-system main / branch cable installation and removal possible

Dividing equipment into subunits possible

Dividing equipment into subunits possible

Individual equipment subunits can be checked separately

Individual equipment subunits can be checked separately

Total cost reductions and great savings in setup time

By introducing the S-LINK, you can reduce the total cost of system construction to one-fifth. Total costs including for materials go down dramatically and, by decreasing the workload, construction time is lessened which means you can easily meet that tough deadline.
The S-LINK system:

● A hardware-only construction makes layout design simple
● With hook-up connectors, construction time is greatly reduced
● Layout modifications made easy
● Equipment divided into separate segments make for easy debugging
● Segmented equipment can be easily interlinked with commercially available connectors

Total cost reductions and great savings in setup time

Auxiliary materials reduced

Great reductions in auxiliary materials such as cable racks, cable ducts, intermediate terminal blocks, and cables. This system also contributes greatly to the reduction waste caused by cutting cable ends.

Auxiliary materials reduced

Space-saving

Because of great reductions in the amount of intermediate terminal blocks and cables needed, you can save space and minimize the size of your control board and machines.
This will finally let you put all that wasted space to good use.

Space-saving

Upper-level network connection possible

Because it can be connected to any main open network, long-distance and multi-point transmission networks can be constructed enabling a greatly enhanced network upgrade. Also, by wiring up scattered bit-oriented I/O devices that include mostly connected sensors and switches, an efficient wire-saving layout can be realized. If exporting equipment that was setup with any open network, it can be made to correspond to different networks just by installing an S-LINK gateway controller with the entire S-LINK system left as it is.

Upper-level network connection possible
Title 2D CAD DATA 3D CAD DATA

Applications

Distributed installation

■Automatic storage
Automatic storage

Because conveyors have multiple I/O device points, wire-saving and construction efficiency are the key to lowering overall costs. Other systems may be wire-saving but if they can't prove useful for long-distance distribution lines and be reliable, then they are useless. On this point, the S-LINK system offers a total wiring length of 400 m 1312 ft, 800 m 2625 ft when using booster, with reliable T-branch I/O device connections that can be mounted in any desired location.
Because T-branching renders layout designing simple, not only is it a wire-saving and construction efficient system, but you can even save time in the actual design stage.
In addition, you can divide main and branch cables in mid-system with commercially available connectors and terminals so the time it takes to setup your conveyor decreases greatly.

■Parking garage
Parking garage

The S-LINK system is very suitable to wire up car detection sensors in a large parking garage.
It reduces wires and installation time.

■Display panel control
Display panel control

Display equipment can be mounted in automobile production lines to notify operators when malfunctions occur or just to keep a reliable count of units in each line.
Because each type of display equipment shows variegated data, they necessitate a great amount of wiring. This wiring must be conducted in very large factories requiring a substantial amount of cables and wires. A wire-saving system in this situation would be most effective.
Using the S-LINK system means that even display equipment can be wired up with just one flat cable, and clearing up all the bulky wiring inside the display panels themselves and realizing great material cost savings as well as a reduced workload.

Integrated installation

■Automatic assembly machine
Automatic assembly machine

The wire-saving system is being greatly emphasized even for assembly lines crowded with multiple I/O devices.
Also, to enhance productivity, using a wire-saving system is the key to reliability and avoiding the occurrence of troubles.
In the S-LINK loop wiring, the system maintains signal transmission even when the loop may break at any one place.
Also, the controller displays disconnected unit address. Further, when excess current flows or short-circuit occurs in the signal transmission lines, the signal transmission is stopped to protect the system.
S-LINK is a wire-saving system optimal for the automatic assembly machinery.

■Turntable
Turntable

The wiring of I/O devices mounted on a rotating board (turntable) used to be quite a difficult task. Because a slip ring with the same number of terminals as wires had to be used.
Therefore, there have been difficulties such as employing a large slip ring or reduction of I/O point count.
S-LINK enables the connection of up to 128 I/O points on a 4-pole slip ring. A compact slip ring can be used without worrying about I/O points.

■Handler
Handler

"The handler" as the IC test equipment uses multiple sensors.
Cost reduction or downsizing depends on how to reduce these wires and to save space.
S-LINK realizes wire-saving and space-saving; hence these problems are solved all at once.

■Parts picking system
Parts picking system

Many small picking sensors are employed in the parts picking system in order to verify the correct selection of components.
The number of input points is required as much as the number of shelves, the number of output points is also required to be the same in adopting the operational indicators.
S-LINK system greatly contributes to wire-saving both in I/O points and in space. Also, extra shelves can be added easily.

Order guide

System layout

>> System layout (PDF)open new window

 

 

 

S-LINK control units

Designation Appearance
(Note)
Model No. Description
S-LINK
controller
SL-CU1A It supplies the synchronization signal to the complete system to send and receive I/O data from external devices correctly. It also monitors the signal transmission line, and specifies the addresses of the disconnected devices if the line breaks, etc.
FPΣ
S-LINK
unit
FPG-SL
(AFPG780)
It controls the S-LINK system by directly connecting to the FPΣ series.
FP0
S-LINK
Control
unit
FP0-SL1
(AFP02700)
It controls the S-LINK system by directly connecting to the FP0 series.
FP2SH
S-LINK
unit
FP2-SL2
(AFP2780)
It controls the S-LINK system by directly connecting to the FP2SH series.
Mitsubishi
Electric PLC
bus S-LINK
controller
SL-MEL-Q It can be directly connected to the bus line of the MELSEC-Q series PLC manufactured by Mitsubishi Electric Corp.
(Has S-LINK controller as well as PLC input and output connector functions so you don't have to prepare for these items. Also, it doesn't need a PLC input or output module.)
Yokogawa
Electric PLC
bus S-LINK
controller
SL-FAM3 It can be directly connected to the bus line of the FA-M3 series PLC manufactured by Yokogawa Electric Corp.
(Has S-LINK controller as well as PLC input and output connector functions so you don't have to prepare for these items. Also, it doesn't need a PLC input or output module.)
PC/AT S-LINK
control board
SL-PCAT It can be fitted into the expansion slot (ISA bus) of PC/AT series or compatible to control the S-LINK system.
(Has S-LINK controller as well as PLC input and output connector functions so you don't have to prepare for these items.)
PC/104 bus
S-LINK control
board
SL-PC104 Controls the S-LINK system by directly coupling (stack) the PC/104 bus line to a PC/104 bus compatible PC board or panel computer.
(Has S-LINK controller as well as PLC input and output connector functions so you don't have to prepare for these items.)
Note: Components with "CE" mark conform to the CE marking EMC Directive.
The following condition must be met to conform to EN 61000-6-2.
• Conditions
(1)Cable length between the main power supply and the S-LINK control unit should be less than 10 m 32.808 ft.
(2)When the power is supplied from S-LINK control unit to S-LINK I/O devices at a cable distance of more than 10 m32.808 ft add a surge absorber between 24 V and 0 V at a cable distance of less than 10 m 32.808 ft, or use a local power supply at a cable distance of less than 10 m 32.808 ft from each S-LINK I/O device.

Products for open network

Designation Appearance
(Note)
Model No. Description
S-LINK
gateway
controller for
CC-Link
SL-GU1-C S-LINK gateway controller for connection to open network CC-Link, promoted by Mitsubishi Electric Corp.
Note: Components with "CE" mark conform to the CE marking EMC Directive.
The following condition must be met to conform to EN 61000-6-2.
• Conditions
(1)Cable length between the main power supply and the S-LINK control unit should be less than 10 m 32.808 ft.
(2)When the power is supplied from S-LINK control unit to S-LINK I/O devices at a cable distance of more than 10 m32.808 ft add a surge absorber between 24 V and 0 V at a cable distance of less than 10 m 32.808 ft, or use a local power supply at a cable distance of less than 10 m 32.808 ft from each S-LINK I/O device.

PLC related units

PLC related units
Designation Appearance
(Note 1)
Model No. Description
For input For output
Multi-core
cable PLC
I/O unit
NPN
type
SL-S SL-P This is the Multi-core cable PLC I/O unit for connecting the screwon terminal type PLC with the S-LINK system.
Interfaces I/O data between the S-LINK controller and PLC.
It includes the I/O data conversion circuit for serial to parallel or parallel to serial conversion.
I/O points: 32 points per unit
Connection to screw-on terminal type PLC is by an optional multicore cable attached with an MIL connector on one end.
PNP
type
SL-SP SL-PP
Multi-core
cable
SL-L2000F Length: 2 m
6.562 ft
The multi-core cable attached with an MIL connector on one end links the multi-core cable PLC I/O unit to a screw-on terminal type PLC I/O module.

Notes:

1) Components with "CE" mark conform to the CE marking EMC Directive.
However, note that for the multi-core cable PLC I/O units to conform to CE marking EMC Directive, it is necessary to use cascade cable SL-F70, SL-F150 or SL-F250, control cable SL-C2000F and multi-core cable SL-L2000F.
2) In case the output circuit of the PLC output module contains capacitive components for improving the noise characteristics, since it is possible that the multi-core cable PLC output units SL-P, SL-PP may not be able to receive the signal correctly, please use output modules which have an output circuit capacitance of 0.01 μF or less.
3) Since the multi-core cable PLC output units SL-P, SL-PP are high input impedance, time division input type devices, please use PLC output modules whose output circuit can operate at a load current of even 0.1 mA.

PLC related units

PLC related units
Designation Appearance
(Note 1)
Model No. Description
For
input
For
output
PLC input
connector
PLC output
connector
Fujitsu Component
connector specs.

MIL connector specs.

PLC input connectors
PLC output connectors
(same shape) (Note 2)

The listed PLC I/O modules (NPN I/O type) allow the mating PLC I/O connector to be plugged on them for signal transmission between the PLC and the S-LINK controller.
(The PLC I/O connector converts I/O data from serial to parallel, and vice versa.
I/O points: 32 points per connector)
SL-S1 SL-P1 Please refer to the following table.
SL-S2 SL-P2
SL-S3 SL-P3
SL-S4 SL-P4
SL-S5 SL-P5
SL-S6 SL-P6
SL-S7 -
End
connector
SL-E It must be connected at the end of the last PLC I/O connector.
Cascade
cable
SL-F70 Length: 70 mm
2.756 in
It links PLC input / PLC output connectors.
SL-F150 Length: 150 mm
5.906 in
SL-F250 Length: 250 mm
9.843 in
SL-F1000 Length: 1,000 mm
39.370 in
Control
cable
SL-C1000 Length: 1 m
3.281 ft
It links the S-LINK controller and the first PLC I/O connector.
SL-C2000 Length: 2 m
6.562 ft
SL-C5000 Length: 5 m
16.404 ft
SL-C2000F Length: 2 m
6.562 ft
Model No. Description
Manufacturer PLC PLC input
module (Note 4)
PLC output
module (Note 4)
SL-S1 SL-P1 Panasonic
Industrial Devices
SUNX Co., Ltd.
FPΣ
(Excluding the
FPG-C32T)
FPG-XY64D2T
(X side)
FPG-XY64D2T
(Y side)
FP2 FP2-X32D2 FP2-Y32T
Toshiba Machine
Co., Ltd.
TC200 TC64DI TC64DON
SL-S2 SL-P2 Fuji Electric FA
Components &
Systems Co.,
Ltd.
NS series NS-X64-1
NS-XY64-1(X side)
NS-Y64-T1
NS-XY64-1(Y side)
F55 NV1X3204
NV1X3204-W
NV1X3206
NV1Y32T05P1
F70 NC1X3204
NC1X3204-3
NC1X3206
NC1X6404
NC1X6406
NC1W6406T(X side)
NC1Y32T05P1
NC1Y64T05P1-1
NC1W6406T(Y side)
F80H, F120H
F120S
F140S
F15XS
FTU125A
FTU126A
FTU127C
FTU612A(X side)
FTU222A
FTU227C
FTU612A(Y side)
SL-S3 SL-P3 Fuji Electric
FA Components
& Systems Co., Ltd.
SX seriesSPH NP1X3206-W
NP1X6406-W
NP1Y32T09P1
NP1Y64T09P1
Mitsubishi
Electric Corp.
AnS A1SX41
A1SX42
A1SH42(X side)
A1SY41
A1SY42
A1SH42(Y side)
AnN, AnA
AnU, QnA
QnAs
AX42
AH42(X side)
AY42
AH42(Y side)
Q QX41, QX42 QY41P, QY42P
A2CJ AJ35TC1-32D AJ35TC1-32T
SL-S4 SL-P4 Sharp
Manufacturing
Systems Corp.
JW20, JW20H
JW30H
JW-234N
JW-264N
JW-232S
JW-262S
JW50H JW-34NC
JW-64NC
JW-32SC
JW-62SC
SL-S5 SL-P5 Omron Corp. CJ1 CJ1W-ID231
CJ1W-ID261
CJ1W-MD261(X side)
CJ1W-OD231
CJ1W-OD261
CJ1W-MD261(Y side)
CS1 CS1W-ID231
CS1W-ID261
CS1W-MD261(X side)
CS1W-OD231
CS1W-OD261
CS1W-MD261(Y side)
CVM1, CV
C500
C1000H
C2000H
C500-ID219 C500-OD213
C200H
series
C200H-ID216
C200H-ID217
C200H-OD218
C200H-OD219
CQM1 CQM1-ID213 CQM1-OD213
Hitachi Ltd. EH-150 EH-XD32 EH-YT32
Yokogawa
Electric Corp.
FA500 XD64-6N
WD64-6N(X side)
YD64-1A
WD64-6N(Y side)
FA-M3 F3XD32-3N
F3XD64-3N
F3YD32-1A
F3YD64-1A
Toshiba Corp. T3 DI-335
DI-335H
DO-335
Yasukawa
Electric Corp.
GL20, GL40S
GL60S, GL60H
GL70H
- B2604
SL-S6 SL-P6 Hitachi Ltd. H series XDC24D2H YTR24DH
SL-S7 - Yasukawa
Electric Corp.
GL20, GL40S
GL60S, GL60H
GL70H
B2605 -

Notes:

1) Components with "CE" mark conform to the CE marking EMC Directive.
However, note that for the PLC I/O connectors to conform to CE marking EMC Directive, it is necessary to use cascade cable SL-F70, SL-F150 or SL-F250 and control cable SL-C2000F.
2) The PLC I/O connectors use Fujitsu connectors. However, SL-S1, SL-S6, SL-P1 and SL-P6 connectors use MIL connectors.
3) PLC I/O connectors are connectable to S-LINK controller SL-CU1A only.
4) X side and Y side indicate the input and the output connectors, respectively, of the compound input / output module.

S-LINK I/O devices

Designation Appearance
(Note)
Model No. Description
1 channel
I/O unit
SL-CH1 NPN type It can be used as either an input unit or an output unit by switch selection.
Signals, such as from the sensor and limit switch, can be transmitted by the signal transmission line. These signals from the signal transmission line can turn ON / OFF the transistor output.
SL-CH1-PN PNP type
2 channel
I/O mixed unit
SL-CH21 NPN type 1 input and 1 output are equipped. 1 input device and 1 output device are connectable.
SL-CH21-PN PNP type
2 channel
input unit
SL-CH20 NPN type 2 input devices are connectable.
SL-CH20-PN PNP type
2 channel
output unit
SL-CH22 NPN type 2 output devices are connectable.
SL-CH22-PN PNP type
Connector
I/O unit
8 channel
snapconnector
input unit
SL-T8J 8 NPN inputs 8 input or 8 output devices are connectable with snap male connectors.
The output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line.
SL-T8J-PN 8 PNP inputs
8 channel
snapconnector
output unit
SL-TP8J 8 NPN outputs
SL-TP8J-PN 8 PNP outputs
16 channel
MIL connector
input unit
SL-T16C1 16 NPN inputs Since connection can be made with an MIL connector, 16 input or 16 output devices can be connected to this slim I/O unit.
The output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line.
SL-T16C1-PN 16 PNP inputs
16 channel
MIL connector
output unit
SL-TP16C1 16 NPN outputs
SL-TP16C1-PN 16 PNP outputs
Connector
I/O unit
8 channel
snapconnector
input unit
SL-T8E 8 NPN inputs Up to 8 input or output devices can be easily connected via e-CON.
Also, when there is an abnormality in the signal communication line, the output status just before the abnormality can be preserved since the output unit is equipped with an output hold function.
* For the connector, please separately purchase a commercial product which supports e-CON standards.
SL-T8E-PN 8 PNP inputs
8 channel
snapconnector
output unit
SL-TP8E 8 NPN outputs
SL-TP8E-PN 8 PNP outputs
Note: Components with "CE" mark conform to the CE marking EMC Directive.
Designation Appearance
(Note 1)
Model No. Description
I/O arrayed
terminal unit
Input
terminal
SL-TB4 4 NPN inputs They are screw-on terminal units to which 4, 8 or 16 input devices are connectable. Since power supply terminals have been provided for every two input channel, neat wiring is possible.
SL-TB4-PN 4 PNP inputs
SL-TB8 8 NPN inputs
SL-TB8-PN 8 PNP inputs
SL-TB16 16 NPN inputs
SL-TB16-PN 16 PNP inputs
Output
terminal
SL-TBP4 4 NPN outputs They are screw-on terminal units to which 4, 8 or 16 output devices are connectable. The output unit is incorporated with an output signal hold function, which retains the output state just prior to an error on the signal transmission line.
SL-TBP4-PN 4 PNP outputs
SL-TBP8 8 NPN outputs
SL-TBP8-PN 8 PNP outputs
SL-TBP16 16 NPN outputs
SL-TBP16-PN 16 PNP outputs
  Separate
load power
supply type
SL-TBP4-TY 4 NPN outputs In the case that a malfunction occurs to the output device that is being connected, they enable forced turning OFF of the output device connected to the output terminal without halting the complete S-LINK system, by switching off the load power supply.
SL-TBP8-TY 8 NPN outputs
SL-TBP16-TY 16 NPN outputs
Relay output
terminal unit
4 relay
output
SL-TPR4 4 outputs
(Note 2)
They are terminal units to which 4 or 8 output devices can be connected by slim socket relays that can be easily replaced.
They are incorporated with an output signal hold function which retains the output state just prior to an error on the signal transmission line.
8 relay
output
SL-TPR8 8 outputs
(Note 2)
Sensor block Snap-connector Sensor
main
block
SL-BMJ It allows connection of various kinds of input devices, such as, photoelectric sensors, inductive proximity sensors, limit switches, and push buttons with the snap female connectors. Changes signals from input devices into serial signals and transmits them to the signal transmission line. One SL-BMJ can be extended by one SL-BXJ or two SL-BXs, up to 16 input points.
(It can generate the ORed self-diagnosis output of all the connected devices.
In this case, the first channel gets occupied.)
Extension
block
SL-BXJ It can follow either main block, and allows connection of 8 input devices.
For plug-in unit Sensor
main
block
SL-BM It allows connection of various kinds of plug-in units and changes signals from plug-in units into serial signals and transmits them to the signal transmission line.
One SL-BM can be extended by three SL-BXs or one SL-BX plus one SL-BXJ, up to 16 input points.
(It can generate the ORed self-diagnosis output of all connected units. In this case, the first channel gets occupied.)
Extension
block
SL-BX It can follow either main block, and allows connection of four plug-in units.
Plug-in unit Amplifierseparated
photoelectric
sensor
SU-7J Its thickness is merely 10 mm0.394 in. The sensitivity is automatically set with ease.12 kinds of sensor heads are suitable with it.
(For details, refer to the SU-7/SH series pages.)
Input
terminal unit
SL-TJ1 It allows connection of 1 No. of various kinds of input devices, such as, a photoelectric sensor, an inductive proximity sensor or a limit switch.
S-LINK direct
hook-up
photoelectric
sensor
SL-A11 Thru-beam type 10 m
32.808 ft
These can be hooked up to the S-LINK cable, at any place, without any interface.
SL-A13 Thru-beam type 30 m
98.425 ft
SL-A19 Retroreflective type with polarizing
filters 0.1 to 5 m
0.328 to 16.404 ft
SL-A12 Diffuse reflective type
700 mm27.559 in
S-LINK direct
hook-up picking
sensor
SL-N15 Sensing range:
0.2 to 3 m
0.656 to 9.843 ft
(0.05 to 1 m0.164 to 3.281 ft
when the switch is set to SHORT)
Beam pitch: 25 mm 0.984 in
Sensing height: 100 mm 3.937 in
Sensing object: ø35 mm ø1.378 inor
more opaque object
It is a parts-taking verification sensor with five sensing beams and can be hooked up to the S-LINK cable without any interface.
Both the emitter and the receiver are incorporated with bright orange LED job indicators that are easily visible to the operator.
Picking switch SL-PK01 This picking switch can be installed on pipes. Its compact size (just 90 mm 3.543 in wide) allows it to be installed on small-sized shelving used with compact parts, while its cable with integrated connector and magnetic (Hall element) contactless switch simplify installation and provide freedom in terms of switch operation (back and forth, left and right, and vertically). Up to 64 units can be connected to a single S-LINK control unit.

Note:

1) Components with "CE" mark conform to the CE marking EMC Directive.
2) Relay output is "Contact a" only. Further, when replacing the relay, use PA relay (APA3312) manufactured by Panasonic Corporation.

Connectors

Designation Appearance Model No. Description
Hook-up
connector

(Note)
SL-J1A
[10 pcs. per set]
It creates a "T"-branch connection between two S-LINK exclusive flat cables (4-core).
For 0.5 mm2 flat cable to 0.5 mm2 flat cable connection (Gray)
Applicable hook-up pliers: SL-JPS
Cable extension
hook-up
connector

(Note)
SL-J3A
[10 pcs. per set]
It can extend the S-LINK exclusive flat cable (4-core).
For 0.5 mm2 flat cable to 0.5 mm2 flat cable connection (Black)
Applicable hook-up pliers: SL-JPS
End hook-up
connector

(Note)
SL-JE
[5 pcs. per set]
It must be connected at the end of the main cable.
For 0.5 mm2 flat cable (Gray)
Applicable hook-up pliers: SL-JPS
Cable attached
end connector
SL-JE-RC
[1 pc.]
When cabtyre cable is used as the main cable, it must be connected at the end of the main cable.
Cable end socketbranch
hook-up
connector

(Note)
SL-JK
[10 pcs. per set]
It enables one I/O device to be connected at the S-LINK exclusive 0.5 mm2 flat cable (4-core) end with the snap male connector (SL-CP□). (Light blue)
Applicable hook-up pliers: SL-JPS
"T"-branch
hook-up
connector
SL-JK1
[10 pcs. per set]
It enables one I/O device to be branched off in the middle of the S-LINK exclusive 0.5 mm2 flat cable (4-core) with the snap male connector (SL-CP□). (Blue)
Applicable hook-up pliers: SL-JPS
4-pin type snap
female
connector

(Note)
SL-CJ1
(White)
[10 pcs. per set]
For 0.08 to 0.2 mm2
(Conductor cross-section area)
Wire dia.: ø0.7 to ø1.2 mmø0.028 to ø0.047 in
This snap female connector is used for plugging into the socket of SL-BMJ or SL-BXJ to connect an input device, or into the snap male connector SL-CP1 or SL-CP2.
Applicable hook-up pliers: SL-JPC

(Note)
SL-CJ2
(Black)
[10 pcs. per set]
For 0.3 mm2
(Conductor cross-section area)
Wire dia.: ø1.1 to ø1.6 mm
ø0.043 to ø 0.063 in
4-pin type snap
male connector

(Note)
SL-CP1
(White)
[10 pcs. per set]
For 0.08 to 0.2 mm2
(Conductor cross-section area)
Wire dia.: ø0.7 to ø1.2 mm
ø0.028 to ø0.047 in
This snap male connector is used for connecting S-LINK I/O devices to SL-T8J(-PN) and SL-TP8J(-PN) 8-channel snap-connector I/O units as well as to SL-JK and SL-JK1 hook-up connectors.
Applicable hook-up pliers: SL-JPC
(for the SL-CP1 and SL-CP2)
SL-JPE (for the SL-CP3)

(Note)
SL-CP2
(Black)
[10 pcs. per set]
For 0.3 mm2
(Conductor cross-section area)
Wire dia.: ø1.1 to ø1.6 mm
ø0.043 to ø 0.063 in

(Note)
SL-CP3
(Greenish blue)
[10 pcs. per set]
For 0.5 mm2
(Conductor cross-section area)
Wire dia.: ø1.7 to ø2.5 mm
ø0.067 to ø0.098 in
Note: For UL compatibility, please contact our office.

Basic units

Designation Appearance Model No. Description
I/O
module
Vertical
type
Input
module
SL-M8 8 inputs These are IC type modules which enable external connection of address setting switches and operation indicators.
They increase the design flexibility.
SL-M16 16 inputs
I/O mixed
module
SL-M4P4 4 inputs
4 outputs
Output
module
SL-MP8 8 outputs
SL-MP16 16 outputs
Horizontal
type
Input
module
SL-M8F 8 inputs
SL-M16F 16 inputs
I/O mixed
module
SL-M4P4F 4 inputs
4 outputs
Output
module
SL-MP8F 8 outputs
SL-MP16F 16 outputs

Optional units

Designation Appearance
(Note)
Model No. Description
Booster SL-BS1A It can extend the signal transmission distance by 200 m 656.168 ft.
A maximum of seven boosters can be connected for one S-LINK control unit.
However, one booster can never be followed by another booster in series.
Handy monitor SL-HM1 It can be connected at any place on the signal transmission line and the I/O states can be checked in batches of 16.
The handy monitor is also incorporated with the S-LINK control functions, so that, for example, it can perform an I/O check on conveyor system segments, still under assembly, even without the S-LINK controller.
Note: Components with "CE" mark conform to the CE marking EMC Directive.

Others

Designation Appearance Model No. Description
8-branch
connector tap
SL-T8PW Connects easily to up to 8 thru-beam type photoelectric sensor emitters or S-LINK I/O devices with snap male connectors.
2-pin type
snap female
connector

(Note)
SL-CJ12 For 0.08 to 0.2 mm2
(Conductor cross-section area)
Wire dia.: ø0.7 to ø1.2 mm
ø0.028 to ø0.047 in
It can be used for cable extension of 2-wire I/O devices by combining with a 2-pin type snap male connector SL-CP□2.
Applicable hook-up pliers: SL-JPC

(Note)
SL-CJ22 For 0.3 mm2
(Conductor cross-section area)
Wire dia.: ø1.1 to ø1.6 mm
ø0.043 to ø 0.063 in
2-pin type
snap male
connector

(Note)
SL-CP12 For 0.08 to 0.2 mm2
(Conductor cross-section area)
Wire dia.: ø0.7 to ø1.2 mm
ø0.028 to ø0.047 in
It can be used for cable extension of 2-wire I/O devices by combining with a 2-pin type snap female connector SL-CJ□2.
Applicable hook-up pliers: SL-JPC

(Note)
SL-CP22 For 0.3 mm2
(Conductor cross-section area)
Wire dia.: ø1.1 to ø1.6 mm
ø0.043 to ø 0.063 in
Exclusive
flat cable
(4-core)

(Note)
SL-RCM100 Length:
100 m
328.084 ft
D line: White (1) S-LINK / S-LINK V exclusive flat cable (4-core)
Conductor cross-section area: 0.5 mm2
Outer diameter: ø2.5 mm ø0.098 in × 4
SL-RCM100-PK D line: White with pink stripe (2)
SL-RCM100-GN D line: White with green stripe(3)
SL-RCM100-GY D line: White with gray stripe (4)
SL-RCM200 Length: 200 m656.168 ft, D line: White (5)
Exclusive
cabtyre cable
(4-core)
SL-CBM100 Length: 100 m328.084ft S-LINK / S-LINK V exclusive cabtyre cable (4-core)
Conductor cross-section area: 0.5 mm2
Outer diameter: ø7.4 mm ø0.291 in
(Hook-up connector cannot be used)
SL-CBM200 Length: 200 m656.168 ft
Exclusive pliers SL-JPS Hook-up connector (SL-J□) can be connected in one grip.
SL-CP3
exclusive pliers
SL-JPE 4-pin type snap male connector (SL-CP3) can be connected in one grip.
Male / female
connector
exclusive
pliers
SL-JPC Snap female connector (SL-CJ1/CJ2, SL-CJ11/CJ12) and snap male connector (SL-CP1/CP2, SL-CP11/CP12) can be connected in one grip.
Address label SL-MA1-SET
[4 sheets. per set]
By sticking the labels on the respective S-LINK devices, the set addresses can be confirmed at one glance. SL-MA1-SET is available in white, pink, green and gray colors, as a 4-sheet set, and is convenient when used by matching the color with that of the S-LINK exclusive flat cable (100 m 328.084 ft type).
DIN rail
mounting
bracket for
SL-CH□
MS-CHx10
[10 pcs. per set]
Mounting bracket enabling the SL-CH□(-PN) I/O units to be mounted onto a 35 mm 1.378 in width DIN rail. They can also be affixed with screws.
(When affixing with screws, arrange two M4 pan-head screws separately.)
I/O unit holder
for SL-CH□
MS-SLH
[5 pcs. per set]
It is used to mount the SL-CH□(-PN) unit.
(Please arrange two M4 pan-head screws separately.)
Note: For UL compatibility, please contact our office.

Accessories

NPS-CV
(Protective cover for the SL-CU1A, SL-BS1A or SL-CU1-485)

 

RF-230
(Reflector for the SL-A19)

 

MS-SL-2
(Mounting base for connector I/O units)

 

Discontinued products

* Substitute products will not guarantee the specifications of discontinued products.
Please check the specification details from catalog before use.

Discontinued product Recommended substitute
Product number Part number Last time buy   Product number Series Remark
SL-BME SL-BME September 30, 2002
To be discontinued
SL-BM,SL-CU1A Sensor & Wire-saving Link System S-LINK 2 models (SL-BM, SL-CU1A) are necessary.
SL-CH21K SL-CH21K September 30, 2008
T
Title 2D CAD DATA 3D CAD DATA


Title FİLE

S-LINK


Title FİLE

For ISA・C・PC/104 bus and OPCN-1 master board

EDS file for SL-GU1-D

PCI bus

CompactPCI bus


Title FİLE

Conditions in use for CE marking conformity (S-LINK)

SL-A

SL-BM

SL-BM (Conditions in use for CE conformity)

SL-BMJ / SL-BXJ

SL-BS1A

SL-BX

SL-CH1 / SL-CH1-PN

SL-CH20 / SL-CH20-PN

SL-CH21 / SL-CH21-PN

SL-CH21K

SL-CH22 / SL-CH22-PN

SL-CJ1/SL-CJ2

SL-CJ12 / SL-CJ22

SL-CP12 / SL-CP22

SL-CPCI

SL-CU1A

SL-FAM3

SL-GU1

SL-GU1-C

SL-GU1-D

SL-HM1

SL-J1A

SL-J3A

SL-JE

SL-JK/SL-JK1

SL-MEL-Q

SL-M□

SL-N15

SL-PC104

SL-PC98

SL-PCAT

SL-PCI

SL-S/SL-SP/SL-P/SL-PP

SL-S□/SL-P□

SL-T16C1(-PN)/SL-TP16C1(-PN)

SL-T8E(-PN)/SL-TP8E(-PN)

SL-T8J(-PN)/SL-TP8J(-PN)

SL-TBAD4

SL-TBDA1

SL-TB□-PN/SL-TBP□-PN

SL-TB□/SL-TBP□(-TY)

SL-TJ1

SL-TPR4/SL-TPR8

SL-VMES2

SL1 Caution