Ultra-compact Ionizer ER-V


A new style of charge removal
New ultra-compact, high-performance ionizer!

CE Marking cTUVus Certificate

UL , CE , CSA Approved
CE : EMC Directive
UL, CSA : Certified by TÜV SÜD America Inc. (NRTL)(ER-VS02 only)

Features

ER-VS02

Optimized discharge needle tip shape for even more stable ion-producing power [ER-VS02]

Optimized discharge needle tip shape for even more stable ion-producing power

The discharge needle tip’s spherical shape enables more stable ion production while making it less likely that the shape of the tip will change over time as a result of electrical discharge.

Improved maintenance cycle [ER-VS02]

Stable ion-producing performance contributes to a longer maintenance cycle, which has been improved to one month or longer* in the ER-VS.
(*When used in an operating environment that complies with Panasonic requirements)

Selection of nozzles for different applications

In addition to eight standard nozzle types, including shower and tube nozzles, We offers a range of differently shaped nozzles (including made-to-order models).

Ultra-compact design accurately removes charges of objects even from narrow spaces

The main unit is merely 109 x 27 x 28 mm 4.291 x 1.063 x1.102 in, so it can easily be combined with other devices and also be installed as an add-on. Furthermore, the highvoltage power supply is built-in, so no extra space is required except for the ionizer itself.

Ultra-compact design accurately removes charges of objects even from narrow spaces

Produces excellent ion balance

The adoption of high-frequency AC method allows extremely stable ion balance to be achieved. Because the ion balance is not affected by the pressure of air supplied or by the setup distance, no troublesome adjustments are required after setup.

Produces excellent ion balance

High performance with no controller needed

A full range of functions have been provided with full consideration given to ease of use in the workplace. No separate controller is needed.

Discharge halt input
A signal from an external device can be used to turn discharge ON and OFF.
Sensors can be used to detect the objects so that the ion air is generated only when required.

Discharge halt input

Discharge indicator
The discharge ON / OFF status can be checked using an LED display. This lets you avoid problems such as when the power is on but no discharge is occurring.

Discharge indicator

Easy discharge needle maintenance

The discharge needle can be removed from the rear of the main unit, so there is no need to remove the nozzle when replacing the needle. Maintenance is easy even when the ion air outlet is located close to the object.

Easy discharge needle maintenance

Low power consumption and low-voltage wiring

The power supply voltage is 24 V DC, and the power consumed is only 70 mA.
In addition, safety is enhanced because no high-voltage cables are required.

Safe design

A "checking function" and an "abnormal discharge monitoring function" are provided to notify the operator when it is time to clean or replace the discharge needle and to prevent discharge problems from occurring. Each function has an LED display to use for checking. The output from each function can also be used to externally monitor the status of the ionizer during operation.

Safe design

Discharge needle is covered by the nozzle

The discharge needle does not protrude from the main unit, so it cannot be touched by accident. Furthermore, no leaks can occur when it is brought close to metallic objects.

Discharge needle is covered by the nozzle

Title 2D CAD DATA 3D CAD DATA

ER-VS02, ER-VS01(+ER-VAB020)

ER-VS02, ER-VS01(+ER-VAB032)

ER-VS02, ER-VS01(+ER-VAB065)

ER-VS02, ER-VS01(+ER-VAJT-64)

ER-VS02, ER-VS01(+ER-VAK10)

ER-VS02, ER-VS01(+ER-VAK30)

ER-VS02, ER-VS01(+ER-VAK50)

ER-VS02, ER-VS01(+ER-VAS)

ER-VS02, ER-VS01

Applications

Charge removal of FPD glass surfaces
Charge removal of FPD glass surfaces
Charge removal and dust removal of lenses
Charge removal and dust removal of lenses
Pinpoint charge removal of electronic components
Pinpoint charge removal of electronic components
Prevent discharge damage in circuit board LEDs
Prevent discharge damage in circuit board LEDs
Charge removal and dust removal of relay and switch contacts
Charge removal and dust removal of relay and switch contacts

Order guide

Ionizer main unit

Nozzle and cable with connector are not supplied with the ionizer main unit. Please order them separately.

Type Appearance Charge removal time
(±1,000V→±100V)
Ion balance Model No.
Spot type
* The photograph shows the unit fitted with a shower nozzle.
1 sec. or less (Note) ±10 V or less (Note) ER-VS02
Note : A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa while the shower nozzle is in use.
(Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)

Nozzles

Nozzle is not supplied with the ionizer main unit. Please order it separately.

Type Appearance Model No. Description
Shower
nozzle
ER-VAS Air dispersal type
Straight bar
nozzle
(Note 1)
ER-VAB020 Effective charge removal length 200 mm 7.874 in Straight-line bar containing a series of holes
ER-VAB032 Effective charge removal length 320 mm 12.598 in
ER-VAB065 Effective charge removal length 650 mm 25.591 in
Shape-preserving tube
(Note 2)
Joint
nozzle
ER-VAJK Joint nozzle for ionizer main unit and shape-preserving tube
  ER-VAK10 Tube length 112 mm4.409 in Bends easily and holds its bent shape so the tube does not need to be secured
(Tube diameter: ø10 mm ø0.394 in
Minimum bending radius: R40 mmR1.575 in)
ER-VAK30 Tube length 312 mm12.283 in
ER-VAK50 Tube length 512 mm20.157 in
Conductive tube Joint
nozzle
ER-VAJT-64 Joint nozzle for ionizer main unit and conductive tube
  ER-AT50 Tube length 500 mm19.685 in This flexible conductive tube is suitable for a variety of applications since it can be cut to the desired length.
(Tube diameter: ø6 mm ø0.236 in
Minimum bending radius: R15 mmR0.591 in)
Tube joint set
(Note 3)
ER-VAB-AT Tube length 500 mm19.685 in This set includes flexible, free-cut conductive tube and a joint nozzle.
Tube diameter: ø8 mm ø0.315 in; minimum bending radius: R25 mmR0.984 in; compatible nozzles: straight nozzles [except ER-VAB065]
ER-VAB-ATL Tube length 500 mm19.685 in

Notes:

1) In addition to the effective charge removal lengths listed above, we can supply models with an effective charge removal length ranging from 100 to 640 mm 3.937 to 25.197 in in 10 mm 0.394 in increments on a special-order basis.
Model number: ER-VAB□□□N (for an effective charge removal length of 180 mm: ER-VAB018N)
For details, please contact our sales office.
2) We can also supply shape-preserving tubes at lengths shorter than the tube lengths noted above on a special-order basis. For details, please contact our office.
3) For details, please contact our office.

Cables with connector

Cable with connector is not supplied with the ionizer main unit. Please order it separately.

Appearance Model No. Description
ER-VCCJ2 Length: 2 m 6.562 ft,
Net weight: 52 g approx.
0.15mm2 8-core cabtyre cable with connector
Cable outer diameter: Ø4.2 mm Ø0.165 in
ER-VCCJ5 Length: 5 m 16.404 ft,
Net weight: 120 g approx.
ER-VCCJ9 Length: 9 m 29.528 ft,
Net weight: 240 g approx.

Discontinued products

 

* Substitute products will not guarantee the specifications of discontinued products.
Please check the specification details from catalog before use.
Discontinued products Recommended substitute
Product
name
Product
number
Last time buy   Product
number
Series Remark
Ultra-compact Ionizer ER-VS01 September 30, 2013
To be discontinued
ER-VS02 Ultra-compact Ionizer ER-V  
Title 2D CAD DATA 3D CAD DATA

ER-VS02, ER-VS01(+ER-VAB020)

ER-VS02, ER-VS01(+ER-VAB032)

ER-VS02, ER-VS01(+ER-VAB065)

ER-VS02, ER-VS01(+ER-VAJT-64)

ER-VS02, ER-VS01(+ER-VAK10)

ER-VS02, ER-VS01(+ER-VAK30)

ER-VS02, ER-VS01(+ER-VAK50)

ER-VS02, ER-VS01(+ER-VAS)

ER-VS02, ER-VS01



Title FİLE

ER-VS01

ER-VS02

Static Control Devices Selection Guide


Title FİLE

Title FİLE

ER-VS01

ER-VS02 INSTRUCTION MANUAL

ER-AF [Mini line filter]

ER-ATH [Conductive tube holder]

ER-VAJK/ER-VAK□

ER-VAJT-64 [Conductive tube Joint nozzle]

ER-VAPS1 [AC Adapter]

ER-VAS/ER-VAB□ [Shower nozzle / Straight bar nozzle]