Thin-type Ionizer ER-VW


Selectable charge removal layout
Nozzle angle adjustment and joint layout can be selected as desired

Thin-type Ionizer ER-VW
CE Marking cTUVus Certificate

UL , CE , CSA Approved
CE : EMC Directive
UL, CSA : Certified by TÜV SÜD America Inc. (NRTL)

Features

Nozzle angle adjustment mechanism

The angles of the two nozzles can be adjusted within a range of approximately 190° by screwing down the ends of the nozzles. After adjusting the angle, turn the ends of the nozzles to tighten them and secure them at that angle.
This allows the nozzle angles of the ER-VW to be adjusted easily after installation.

Nozzle angle adjustment mechanism

Easy connection layout possible

The joint kit (optional) can be used to connect up to a maximum of 5 ER-VW units. The air supply part is connected via quick connection joints, and the power supply and input / output signals can also be connected easily using connection cables with connectors at both ends.
Multiple ER-VW units can be connected together to provide charge removal layouts that suit the target equipment.

Easy connection layout possible

Connection application example

Easy connection possible

Minimum air consumption 15 l/min. (ANR)

ER-VW can utilize air flow levels starting from a minimum of 15 l/min. Because the amount of air consumed is so low, the loads placed on air supply equipment can be reduced and costly clean air can be used much more economically.

Minimum air consumption 15 l/min. (ANR)

No damage to electronic devices from inverse charging

A high-frequency 68,000 Hz AC corona discharge is used, so that (+) ions and (-) ions are emitted in rapid alternation. Because there are none of the sudden ion discharges that occur with other types, there is no tendency to partial oppositely-charging even when charge removal insulators with different localized charges, so that any damage to electronic devices can be avoided.

No damage to electronic devices from inverse charging

Produces excellent ion balance

The adoption of high-frequency AC method allows extremely stable ion balance to be achieved. The ion balance is not affected by the pressure of air supplied and the setup distance, so no troublesome adjustments are required after setup.

Produces excellent ion balance

Compact and ultra-thin design

The thickness of the unit is 18.9 mm 0.744 in. Even so, the nozzle angles can be adjusted, so that they can still be installed in places where there are space restrictions, such as inside other equipment or along several adjacent production lines.

Compact and ultra-thin design
Notes:
1) Minimum width dimensions after nozzle angle adjustment
2) Maximum width dimensions after nozzle angle adjustment

Air supply monitoring function

This function causes discharging to stop automatically if the supply of air drops below a certain pressure. Notification of this is given when the AIR indicator lights and the discharge output (DSC) turns off. This prevents objects which are not charged from being overlooked when the air supply has been stopped.

Air supply monitoring function

The functions support accurate charge removal

In addition to the air supply monitoring function, the ER-VW is equipped with the following functions to ensure accurate charge removal.

The functions support accurate charge removal

- Discharge halt function:
Uses external input to forcibly stop discharge.
- Check function:
Uses the CHECK indicator and output to notify the operator when it is time to clean or replace the discharge needle.
- Abnormal discharge monitoring function:
Uses the ERROR indicator and output to notify the operator when a problem with discharge occurs, and stops discharge. It can be canceled by means of reset input.
- Discharge output:
Output is ON during discharging. This lets you check when discharging is being carried out.
- Check output:
Output turns ON when the discharge needle is dirty.
- Error output:
Output turns OFF when there is a problem with discharging (normally it is ON). It also allows you to check the power supply to the ionizer.

Title 2D CAD DATA 3D CAD DATA

ER-VW

Applications

Removing charges from IC trays
Removing charges from IC trays
Removing charges during pickup from dicing tape
Removing charges during pickup from dicing tape
Removing charges from adjacent lead frame conveyor lines
Removing charges from adjacent lead frame conveyor lines
Removing charges surfaces of CDs / DVDs
Removing charges surfaces of CDs / DVDs
Removing charges from LCD module clamps
Removing charges from LCD module clamps
Removing charges during cell production
Removing charges during cell production

Order guide

Ionizer main unit

One each of connector attached cable (length 0.5 m 1.640 ft), end connector and lead wire for connecting F.G. are supplied with the ionizer main unit.

Type Appearance Charge removal time
(±1,000V→±100V)
Ion balance Model No.
Spot type 1 sec. or less (Note 1) ±10 V or less (Note 1) ER-VW (Note 2)
Note 1 : A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa.(Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Note 2 : The PNP output type is also available.